This TCM-T3000 can monitor and analyze the power quality of the grid and measure the positive, negative, zero sequence components and unbalance factor. This TCM-T3000 can monitor and analyze the Voltage and current waveforms for the better understanding the power quality and distortion.
π TCM-T3000 Power Quality Analyzer β Features & Specifications
Measurement & Accuracy
1. Three-Phase Electrical Parameter Measurement β Measures voltage and current (phase-to-phase, phase-to-neutral) for 3P3W/3P4W systems and single-phase circuits.
2. Wide Voltage & Current Range β Voltage: 0β690V (secondary), up to 9999kV via PT; Current: 0β6A (secondary), up to 9999kA via CT.
3. High Accuracy β Voltage & Current: Β±0.1%; Active/Reactive Power: Β±0.2%; Power Factor: Β±0.2%; Frequency: Β±0.01 Hz; Active Energy: Class 0.2S; Reactive Energy: Class 2.
Compliance Standards: IEC 61000-4-30 (Class A), IEC 61557-12 (Power metering & monitoring devices).
4. Full Spectrum Power Measurement β Active (P), Reactive (Q), Apparent (S) for each phase and total; Four-quadrant power analysis.
5. Real-Time Frequency & PF Monitoring β Frequency: 45β65 Hz (Β±0.01 Hz); Power Factor PF1/2/3 & total; CosΟ1/2/3.
6. Advanced Harmonic & Distortion Analysis β Harmonics up to 51st order; interharmonics (2ndβ51st); THD; crest factor; k-factor.
Energy Metering & Demand
7. Bi-Directional Energy Metering β Import/export of active, reactive, apparent, and fundamental energy with per-phase values.
8. Energy Storage Capacity β Up to 99.9 billion kWh with resolution as fine as 1 Wh or 1 varh.
9. Tariff Management System β 8 tariffs, 12 time zones, 90 programmable holidays; supports daily, monthly, and historical tariff reports.
10. Demand Analysis β Present, previous, forecast, max demand; fixed/sliding block modes with programmable demand intervals.
11. Demand Setup β Sliding Block and Fixed Block methods with configurable sliding time & cycle periods.
Power Quality & Disturbance Analysis
12. Voltage Quality Monitoring β Detects deviations, dips, swells, interruptions, and rapid voltage changes (RVC).
13. Waveform Capture β Transient capture with 80 ΞΌs resolution including event waveforms.
14. Voltage Flicker Monitoring β Short-term (10 min) and long-term (2h) flicker values with timestamps.
15. Unbalance Detection β Positive, negative, and zero-sequence voltage/current unbalance.
16. Compliance & Standards β EN 50160 automatic reporting; ITIC/SEMI F47 curve analysis; IEC 61000-4-30 Classification of A.
Additional Standards: IEC 62586 (PQ measurement in power supply systems).
Logging & Storage
17. Event & SOE Recording β Up to 1024 events with timestamps, logs for power loss/restart, alarms, and user changes.
18. Power Quality Event Log β 1024 PQ events stored with duration, values, and waveforms.
19. Data Freezing β Selectable intervals (1β1440 min) for energy and power records.
20. High Storage Capacity β Retains years of log and event data with timestamping.
21. Custom Modbus Address Mapping β 60 programmable registers for SCADA/EMS/BMS integration.
Alarms & Control
22. Programmable Alarms β For voltage, current, power, frequency, PF, THD, harmonics, flicker; with hysteresis, delay, and logic.
23. Relay Output Control β 4Γ relay outputs (250VAC/30VDC, 5A) configurable for alarms, ON/OFF, or load shedding.
24. Digital Inputs β 4Γ dry contacts for breaker monitoring or pulse counting (built-in 24V DC).
25. Pulse Output β Photocoupler-isolated energy pulse for calibration.
26. Alarm Visualization β Dedicated screen for alarm logs, counters, and events.
27. Custom Alarm Logic β Configurable relay actions and logic for automation.
Communication & Integration
28. RS-485 Communication β Dual RS-485 ports, 2.4β115.2 kbps; Modbus RTU protocol; up to 32 devices.
29. Ethernet & Web Server β Built-in web server for monitoring, configuration, and data download.
30. Protocols Supported β Modbus TCP/IP, IEC 61850, BACnet/IP (via FM-24 expansion).
31. Wireless Options β Optional GPRS/SMS alerts and Wi-Fi connectivity.
32. Custom Modbus Mapping β Seamless integration with SCADA, EMS, and BMS.
33. Real-Time Updates β 1-second refresh rate across all measured parameters.
34. Expandable Communication β FM2 (DI), FM-24 (DO), FM11 (RS-485), FM24 (Ethernet/Web/IEC 61850).
User Interface & Display
35. 5-Inch TFT Display β Color display with zoom, waveform, phasor, harmonics visualization.
36. Touch Key Navigation β Intuitive menu navigation with programmable default screens.
37. Password Protection β Programmable security; default password: 0001.
38. Multi-Language Interface β Supports multiple languages, brightness and backlight controls.
39. UI Customization β Configurable menus, scaling, and display options.
System & Synchronization
40. Time Synchronization β Via Modbus, NTP, IRIG-B, or Web; RTC drift β€0.5s/day.
41. Programmable Reset Functions β Reset energy, demand, max/min, PQ events, SOE, EN50160 logs.
42. Firmware & Calibration β Long-term accuracy with firmware upgrade support.
Mechanical & Environmental
43. Compact Design β 144 Γ 144 Γ 80 mm; panel-mount with standard cutout.
44. Protection Ratings β IP54 (front), IP20 (rear).
45. Auxiliary Power Supply β 80β270V AC/DC, 50/60 Hz Β±5%, β€10 VA.
46. Operating Conditions β Temp: -25Β°C to +70Β°C; Humidity: 5β95% RH; Altitude β€2000 m (CAT III).
47. Safety Compliance β IEC 61010-1 (CAT III 300V), double insulation, Pollution Degree 2.
48. EMC Standards β IEC 61000-4-2 (ESD), -3 (RF immunity), -4 (EFT/Burst), -5 (Surge), -8 (Magnetic fields).
49. Industrial-Grade Reliability β Isolation, noise immunity, robust design.
Applications
50. Energy Audits & Diagnostics β For compliance verification and PQ assessments.
51. Generator & Facility Monitoring β Accurate monitoring of generators, transformers, loads.
52. Integration with Industrial Systems β SCADA/EMS/BMS compatibility with IEC 61850, Modbus, and IEC 62586.
53. Load Analysis & Optimization β Identifies PQ issues, supports efficiency and cost reduction.
β Standards Compliance (TCM-T3000)
IEC 61000-4-30 (Class A) β PQ measurement methods.
IEC 62586 β Power Quality measurement in power supply systems.
IEC 61557-12 β Power metering & monitoring devices (PMD).
IEC 61010-1 β Safety (Measurement Category CAT III 300V).
IEC 50160 β Voltage characteristics of electricity supplied by public distribution systems.
IEC 61850 β Communication networks & systems in substations.
IEC 61000-4-2/-3/-4/-5/-8 β EMC immunity (ESD, RF fields, EFT/Burst, Surge, Magnetic).
GB/T 39853, GB/T 18216.12, GB/T 17626 series β Chinese equivalents of IEC PQ, PMD, and EMC standards.
ITIC & SEMI F47 curves β Voltage disturbance ride-through compliance.
β Now the list includes IEC 61850 and IEC 50160 explicitly, and all compliance standards are grouped under the relevant features.